iSCSI MPIO network setup - how many NICs do I need?

$
0
0

Hello, I'm setting up a FreeNAS box on our network with iSCSI to store backups and other data. My question is about how to configure networking on ESXi.

 

According to Freenas docs and forum discussions, each Freenas interface needs to be on a separate subnet. The vmware iscsi mpio doc states "Enabling multipathing removes the ability to route to storage. The storage and the VMkernel port must have an IP address in the same network".

 

Here's what I have for iSCSI interfaces on all my storage devices:

FreeNAS storage - 4x1GB Intel NICs

Cisco NAS storage - 2x1GB NICs

IBM SAN storage - 2x1GB NICs

Backup server - 4x1GB Intel NICs (Vmware 5.5 vm running Veeam)

 

We have 2 Cisco 3560G switches, and all interfaces are divided up evenly between the 2 switches for redundancy.

 

So if I understand this correctly, if I want to use MPIO and be able to access all 3 of my storage devices above, my backup server needs to have 8 NICs? I was hoping connections to the various storage devices would be able to share NICs, and route traffic between VLANs which reside on the same switch. But if I follow the Freenas best practice and each NIC is on a separate VLAN, then it's impossible to connect everything unless I add more NICs. Am I right in that assumption?

 

Thanks much in advance!


SRM 6.1 vs Stretched Cluster (vMSC)

$
0
0

Hello,

 

A while ago were decided to use SRM for our disaster recovery tool for about 25 vms.  We use a mix of vSphere Replication and Array base replication (Currently using Asyncronous IP replication with a storwize v5000 and an older v7000).  It's been working well for us but the topic of stretched cluster keeps coming back in our internal discussions mostly to be able to balance workload from our main site to our recovery site.  After upgrading everything to version 6, I am now able to move VMs from one vCenter to another but I have to move storage also...  It works well, but the it would be great if we could simply use a standard vMotion and use the replicated storage instead.

 

We've recently acquired 2 new v7000 with hyperswap which offers syncronous replication.  I was told by IBM that in order to move workloads between our 2 sites, I have to eliminate one vCenter thus get rid of SRM.  This redbook also suggest a one vCenter topology.

 

From what I read in this SRM Whitepaper for version 6.1, I can have best of both worlds by configuring SRM with stretched storage.

 

I was wondering if some of you have configured SRM with stretched storage.  I'm curious to know how I could present the same volume to 2 vCenters.

 

Thank you!

Add vCenter 6.5 Identity Source via PowerCLI or Command line

$
0
0

Is anyone aware of anyway to add a AD as LDAP Identity source inside vCenter 6.5? I have found articles related to 6.0 but those utils don't seem to exist in 6.5. Also I haven't had any luck finding a way to script a service to start as automatic (i.e. Auto Deploy & ImageBuilder) so any help would be appreciated.

Re: How to find original CPU

$
0
0

No, nothing going back that far.

Re: vCAC IaaS web component upgrade v.6.2.2 to v.6.2.5 failure - File DynamicOps.ManagementModel.dll not found

$
0
0

Update:  We were able to get this resolved with a VMware vRA support engineer. Needed to re-register assemblies into SQL DB in order for installer to un-register and upgrade them.  Most likely occurred from mutliple install attempts that had failed for other reasons, but left these asemblies as already registered and the installation didn't like that.  Ran following commands:

 

"C:\Program Files (x86)\VMware\vCAC\Server\Model Manager Data\RepoUtil.exe" Assembly-List

 

"C:\Program Files (x86)\VMware\vCAC\Server\Model Manager Data\RepoUtil.exe" model-sqlupdate -f DynamicOps.ManagementModel.dll -v -s vmmip-h4vrod01.lm.lmig.com -d vcac

 

/****** Script for SelectTopNRows command from SSMS  ******/

SELECT TOP 1000 [Id]

      ,[FullyQualifiedName]

      ,[FileName]

      ,[Content]

  FROM [vCAC].[DynamicOps.RepositoryModel].[Assemblies]

 

RepoUtil.exe Model-Install -f DynamicOps.ManagementModel.dll -s "vmmip-h4vrod01.lm.lmig.com" -d "vcac" -c "ManagementModelSecurityConfig.xml" -v

RepoUtil.exe Model-Install -f DynamicOps.AmazonWSModel.dll -s "vmmip-h4vrod01.lm.lmig.com" -d "vcac" -c "AmazonWSModelSecurityConfig.xml" -v

RepoUtil.exe Model-Install -f DynamicOps.UcsModel.dll -s "vmmip-h4vrod01.lm.lmig.com" -d "vcac" -c "UcsModelSecurityConfig.xml" -v

RepoUtil.exe Model-Install -f DynamicOps.ScvmmModel.dll -s "vmmip-h4vrod01.lm.lmig.com" -d "vcac" -c "ScvmmModelSecurityConfig.xml" -v

RepoUtil.exe Model-Install -f DynamicOps.VMWareModel.dll -s "vmmip-h4vrod01.lm.lmig.com" -d "vcac" -c "VMWareModelSecurityConfig.xml" -v

RepoUtil.exe Model-Install -f DynamicOps.VCNSModel.dll -s "vmmip-h4vrod01.lm.lmig.com" -d "vcac" -c "VCNSModelSecurityConfig.xml" -v

RepoUtil.exe Model-Install -f DynamicOps.WorkQueueModel.dll -s "vmmip-h4vrod01.lm.lmig.com" -d "vcac" -c "WorkQueueModelSecurityConfig.xml" -v

RepoUtil.exe Model-Install -f DynamicOps.OpenstackModel.dll -s "vmmip-h4vrod01.lm.lmig.com" -d "vcac" -c "OpenstackModelSecurityConfig.xml" -v

RepoUtil.exe Model-Install -f DynamicOps.ReportsModel.dll -s "vmmip-h4vrod01.lm.lmig.com" -d "vcac" -c "ReportsModelSecurityConfig.xml" -v

-v

Re: vSan disk errors when migrate

$
0
0

Looks like that recommendation is only for all flash, I´m running hybrid. From the blog:

 

I’ve deployed or am going to deploy a Hybrid vSAN cluster.  Am I impacted?

No, the revised sizing guidelines are applicable only to All Flash

Hybrid will continue to use 1:10 caching to usable capacity ratio

Re: Simple & Low Cost BackUp & Data Recovery ?

$
0
0

I think I found a solution to backing up the VMWare virtual servers.  How can I backup all the VMWare Host itself or at least the configuration?  (No backing up the VMs just the Host itself)

 

Are there any straightforward simple solutions for this?

ImageBuilder to apply 5.5 U3_Patch10

$
0
0

I currently have a working auto deploy solution and custom image based on Cisco UCS platform drivers etc. I need to apply the vib updates from Patch 10.

 

Using ImageBuilder to update a custom profile.

 

I know using i.e. add-EsxSoftwarePackage -ImageProfile ESXi55U3_P10_ver4 -SoftwarePackage ????? allows me to add specific vibs i.e. new Cisco drivers etc.

 

How do I update the custom image with all of the ESXi base and other updated vibs and dependencies at once. Can I?  Can i simply state the added software depot zip?

That one step seems to be missing from many of the communities I have searched.

 


Re: snapshot consolidation error

$
0
0

@mahamksorry i haven't seen your reply earlier. i'm definitely going to try this tomorrow.

VMWare Fusion delays

$
0
0

Hi,  Using Fusion 8.5.5. 

 

There are delays every couple of seconds when I enter any kind of data in any program.  Anyone have any fixes?

 

CWGInc

Re: vra 7.2 join provisioned vm to AD

$
0
0

You can create an Active Directory Policy to join VMs to a domain during the provisioning process. You need to add an Active Directory endpoint in vRA using an account with privileges to add computer accounts to the domain. You then configure this AD policy on your business group and can target a specific OU in the AD structure.

Re: ImageBuilder to apply 5.5 U3_Patch10

Dudas en mi primer proyecto

$
0
0

Bueno, mi primer ESXi. Escenario: Tenemos un HP Gen 9 con 48gb ram y 3 sas 15.000 con win 2012.

 

Sobre él corren 4 máquinas virtuales con un WmPlayer.


Escenario final: esos 5 host estén en un ESXi en el Server HP.  Trabajo de 8 a 18 parando, ellos 7x24 casi...

Para ello tengo otro ESXi pasarela sobre un i5 con 16gb de ram, 2ssd 480 gb y otro SATA de 4teras.

Proceso: instalar El Standalone Converter en cada uno y pasarlos al i5, formatear el HP e instalar ESXi 6.5.

Requisito pararles el mínimo de tiempo...

Dudas: hay suficiente RAM en el i5 para los 5? Apenas son 3gb cada...
1. Windows 7 2gb
2. 2003 ad sql 4g
3. 2003 iis 2gb
4. 2008 sql 2g
5. 2012 ad sql navision 4 gigas
ESXi requiere 2gb para arrancar! Total 16gb
ES SUFICIENTE 4gb ese 2012 y en eL SATA DE 4teras? Ocupa unos 600gb entre c y d, no entra en SSD...

Puede tardar 12 o 18h en migrar el 2012, si rinde en el i5 se me ocurre moverlo al i5 con Veeam Quick Migration que sólo requiere un reinicio. Es buena opción? Hay otra?

Qué Raid pongo al HP? Raid 5? Sería 1.2 teras casi. Cómo hago para que el cd de esxi vea ese raid? Tiene sentido instalarlo en un pen usb?


Gracias

Re: Request processing is restricted by administrator

Re: How to find original CPU


Trying to deinstall VM Workstation, get The MSI '' failed. - The folder path 'Virtual Machines' contains an invalid character.

$
0
0

I was trying to create snapshot in VM workstation, keep getting "Error taking snapshot: One of the parameters supplied is invalid". this happens on all VMs - So I thought it must be something common to all the VMs, i.e. the installed VM workstation code so trying deinstall Workstation prior to reinstallation, but keep getting:

 

The MSI '' failed. -

The folder path 'Virtual Machines' contains an invalid character.

 

Googling around returned nothing - have you got any ideas?

Re: SRM 6.1 vs Stretched Cluster (vMSC)

$
0
0

Stretched storage integrations with SRM is different from vMSC (what IBM is referencing when they mention transitioning to a single vCenter).

 

Stretched storage integration with SRM requires specific storage from your array vendor that supports not just synchronous replication, but also the ability to present the same LUN/datastore to both sites/arrays as read-write at the same time AND an SRA that will work with that array and SRM 6.1 or later.

 

For details on stretched storage in the SRM documentation see here: Site Recovery Manager 6.1 Documentation Center

 

For compatibility information see: VMware Compatibility Guide - sra

 

Note that there is a filter option for stretched storage. When I search for IBM and SRM 6.1 w/Stretched storage I see the Storwize SRA ver 3.2 and 3.2.1.

Re: vSan disk errors when migrate

$
0
0

How is your network setup? Is your VSAN on a 1Gb network? vMotion on a different NIC?

 

If they're on the same NIC, you'll probably see congestion on 1Gb. If you're VSAN NIC is using 1GB, you'll probably see congestion more often than you'd like.

Re: ESXi 6.5 VMs wont start

$
0
0

Hello,

 

Just quickly to understand your current setup, so you have 1 host and 1 vCenter running in VMware workstation? or do you have the host running on VMware workstation and vCenter on the host?

 

So with the latest ESXi 6.5 version you will get a host web client, if you go to https://IP Address/ui  it should take you to the host web client. Is that where you are getting the error?

 

You can try adding the following line to your .vmx file for the VM, this should automatically answer any questions when the VM boots:

 

msg.autoAnswer = "TRUE"

 

If this is set as True, try it as False, seen a few articles about this but they say different things and I'm currently rebuilding my lab and have 0 hosts to try it out!

 

 

disable the ability to connect and disconnect devices or to modify device settings in VM

$
0
0

Hi,

I  still did not get how user can disable or connect device to VM if he is using RDP or SSH and has not any access to vCenter console. is this :"

isolation.device.connectable.disable = "TRUE"

isolation.device.edit.disable = "TRUE"  "

can be used if the user has rights on vCenter to edit VM settings ?

 